Indicative image NULL
Category Cable
Type MarineLine YOZp 1,8/3 kV 3 x 150 svs
Uteco Code 1-54-50-16-50-5
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16505
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16505
Description: 3 x 150 svs
Cores: 3
Approx. Outer diameter: 42.1 mm
Net weight (k: 5,083 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Cu
Conductor category: Class 2 = stranded
Core insulation: XLPE (VPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, in movement: -20 / 70 °C
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1.8 kV
Nominal voltage U: 3 kV
Test voltage: 6500 V
Colour outer sheath: Black
Product group: Shipboard low voltage cable
Application: Special Frequency Drive cables. These cables have increased isolation thickness to withstand voltage spikes that can occur in low-voltage frequency drives, and to withstand accelerated aging of the insulation material due to higher frequencies. The tinned copper wire braiding offers excellent EMI protection and mechanical protection. Special types available on request.
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 168 mm
Bending radius during installation: 295 mm
Binde: Polyester tape
Capacity: 90 nF/km
Conductor AC resistance at maximum continuous temperature: 0.16 Ohm/km
Conductor dc resistance @ 20°c: 0.124 Ohm/km
Construction outer shield: tinned copper braiding
Core identification: HD 308 S2
Core lay-up: Concentric layers
Diameter conductor: 19.96 mm
Diameter over braiding: 37.5 mm
Diameter shield wires: 0.4 mm
Inductance: 0.193 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 150 mm²
Nominal outer sheath thickness: 2.3 mm
Reel à 1: (16505 / 8713182080280)
Reel à 500: (16505H X 500/20 / 8713182080273)
Screening: Yes
Series: Shipboard cable
Shape of conductor: Sector-shaped
Sheath marking: {Length} TKF - 3X150 svs - 1,8/3 kV - CS 90 - mbzh - MarineLine YOZp HALOGEN FREE {Batch}
Standardization conductor material: IEC 60228
Standardization sheath material: IEC 60092-360
Tensile load: 6750 N
Indicative image NULL
Category Cable
Type MarineLine YOZp 1,8/3 kV 3 x 185 svs
Uteco Code 1-54-50-16-50-6
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16506
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16506
Description: 3 x 185 svs
Cores: 3
Approx. Outer diameter: 44.2 mm
Net weight (k: 6,147 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Cu
Conductor category: Class 2 = stranded
Core insulation: XLPE (VPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, in movement: -20 / 70 °C
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1.8 kV
Nominal voltage U: 3 kV
Test voltage: 6500 V
Colour outer sheath: Black
Product group: Shipboard low voltage cable
Application: Special Frequency Drive cables. These cables have increased isolation thickness to withstand voltage spikes that can occur in low-voltage frequency drives, and to withstand accelerated aging of the insulation material due to higher frequencies. The tinned copper wire braiding offers excellent EMI protection and mechanical protection. Special types available on request.
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 177 mm
Bending radius during installation: 309 mm
Binde: Polyester tape
Capacity: 90 nF/km
Conductor AC resistance at maximum continuous temperature: 0.124 Ohm/km
Conductor dc resistance @ 20°c: 0.0991 Ohm/km
Construction outer shield: tinned copper braiding
Core identification: HD 308 S2
Core lay-up: Concentric layers
Diameter conductor: 22.46 mm
Diameter over braiding: 39.4 mm
Diameter shield wires: 0.4 mm
Inductance: 0.192 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 185 mm²
Nominal outer sheath thickness: 2.4 mm
Reel à 1: (16506 / 8713182080303)
Reel à 500: (16506H X 500/20 / 8713182080297)
Screening: Yes
Series: Shipboard cable
Shape of conductor: Sector-shaped
Sheath marking: {Length} TKF - 3X185 svs - 1,8/3 kV - CS 90 - mbzh - MarineLine YOZp HALOGEN FREE {Batch}
Standardization conductor material: IEC 60228
Standardization sheath material: IEC 60092-360
Tensile load: 8325 N
Indicative image NULL
Category Cable
Type MarineLine YOZp 1,8/3 kV 3 x 185 svs
Uteco Code 1-54-50-16-50-6
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16506
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16506
Description: 3 x 185 svs
Cores: 3
Approx. Outer diameter: 44.2 mm
Net weight (k: 6,147 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Cu
Conductor category: Class 2 = stranded
Core insulation: XLPE (VPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, in movement: -20 / 70 °C
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1.8 kV
Nominal voltage U: 3 kV
Test voltage: 6500 V
Colour outer sheath: Black
Product group: Shipboard low voltage cable
Application: Special Frequency Drive cables. These cables have increased isolation thickness to withstand voltage spikes that can occur in low-voltage frequency drives, and to withstand accelerated aging of the insulation material due to higher frequencies. The tinned copper wire braiding offers excellent EMI protection and mechanical protection. Special types available on request.
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 177 mm
Bending radius during installation: 309 mm
Binde: Polyester tape
Capacity: 90 nF/km
Conductor AC resistance at maximum continuous temperature: 0.124 Ohm/km
Conductor dc resistance @ 20°c: 0.0991 Ohm/km
Construction outer shield: tinned copper braiding
Core identification: HD 308 S2
Core lay-up: Concentric layers
Diameter conductor: 22.46 mm
Diameter over braiding: 39.4 mm
Diameter shield wires: 0.4 mm
Inductance: 0.192 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 185 mm²
Nominal outer sheath thickness: 2.4 mm
Reel à 1: (16506 / 8713182080303)
Reel à 500: (16506H X 500/20 / 8713182080297)
Screening: Yes
Series: Shipboard cable
Shape of conductor: Sector-shaped
Sheath marking: {Length} TKF - 3X185 svs - 1,8/3 kV - CS 90 - mbzh - MarineLine YOZp HALOGEN FREE {Batch}
Standardization conductor material: IEC 60228
Standardization sheath material: IEC 60092-360
Tensile load: 8325 N
Indicative image NULL
Category Cable
Type MarineLine YOZp 1,8/3 kV 3 x 35 svs
Uteco Code 1-54-50-16-50-0
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16500
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16500
Description: 3 x 35 svs
Cores: 3
Approx. Outer diameter: 25.3 mm
Net weight (k: 1,445 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Cu
Conductor category: Class 2 = stranded
Core insulation: XLPE (VPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, in movement: -20 / 70 °C
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1.8 kV
Nominal voltage U: 3 kV
Test voltage: 6500 V
Colour outer sheath: Black
Product group: Shipboard low voltage cable
Application: Special Frequency Drive cables. These cables have increased isolation thickness to withstand voltage spikes that can occur in low-voltage frequency drives, and to withstand accelerated aging of the insulation material due to higher frequencies. The tinned copper wire braiding offers excellent EMI protection and mechanical protection. Special types available on request.
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 105 mm
Bending radius during installation: 183 mm
Binde: Polyester tape
Capacity: 59 nF/km
Conductor AC resistance at maximum continuous temperature: 0.66 Ohm/km
Conductor dc resistance @ 20°c: 0.524 Ohm/km
Construction outer shield: tinned copper braiding
Core identification: HD 308 S2
Core lay-up: Concentric layers
Diameter conductor: 11.46 mm
Diameter over braiding: 23 mm
Diameter shield wires: 0.3 mm
Inductance: 0.211 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 35 mm²
Nominal outer sheath thickness: 1.6 mm
Reel à 1: (16500 / 8713182080204)
Reel à 500: (16500H X 500/20 / 8713182080198)
Screening: Yes
Series: Shipboard cable
Shape of conductor: Sector-shaped
Sheath marking: {Length} TKF - 3X35 svs - 1,8/3 kV - CS 90 - mbzh - MarineLine YOZp HALOGEN FREE {Batch}
Standardization conductor material: IEC 60228
Standardization sheath material: IEC 60092-360
Tensile load: 1575 N
Indicative image NULL
Category Cable
Type MarineLine YOZp 1,8/3 kV 3 x 35 svs
Uteco Code 1-54-50-16-50-0
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16500
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16500
Description: 3 x 35 svs
Cores: 3
Approx. Outer diameter: 25.3 mm
Net weight (k: 1,445 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Cu
Conductor category: Class 2 = stranded
Core insulation: XLPE (VPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, in movement: -20 / 70 °C
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1.8 kV
Nominal voltage U: 3 kV
Test voltage: 6500 V
Colour outer sheath: Black
Product group: Shipboard low voltage cable
Application: Special Frequency Drive cables. These cables have increased isolation thickness to withstand voltage spikes that can occur in low-voltage frequency drives, and to withstand accelerated aging of the insulation material due to higher frequencies. The tinned copper wire braiding offers excellent EMI protection and mechanical protection. Special types available on request.
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 105 mm
Bending radius during installation: 183 mm
Binde: Polyester tape
Capacity: 59 nF/km
Conductor AC resistance at maximum continuous temperature: 0.66 Ohm/km
Conductor dc resistance @ 20°c: 0.524 Ohm/km
Construction outer shield: tinned copper braiding
Core identification: HD 308 S2
Core lay-up: Concentric layers
Diameter conductor: 11.46 mm
Diameter over braiding: 23 mm
Diameter shield wires: 0.3 mm
Inductance: 0.211 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 35 mm²
Nominal outer sheath thickness: 1.6 mm
Reel à 1: (16500 / 8713182080204)
Reel à 500: (16500H X 500/20 / 8713182080198)
Screening: Yes
Series: Shipboard cable
Shape of conductor: Sector-shaped
Sheath marking: {Length} TKF - 3X35 svs - 1,8/3 kV - CS 90 - mbzh - MarineLine YOZp HALOGEN FREE {Batch}
Standardization conductor material: IEC 60228
Standardization sheath material: IEC 60092-360
Tensile load: 1575 N
Indicative image NULL
Category Cable
Type MarineLine YOZp 1,8/3 kV 3 x 50 svs
Uteco Code 1-54-50-16-50-1
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16501
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16501
Description: 3 x 50 svs
Cores: 3
Approx. Outer diameter: 27.8 mm
Net weight (k: 1,861 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Cu
Conductor category: Class 2 = stranded
Core insulation: XLPE (VPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, in movement: -20 / 70 °C
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1.8 kV
Nominal voltage U: 3 kV
Test voltage: 6500 V
Colour outer sheath: Black
Product group: Shipboard low voltage cable
Application: Special Frequency Drive cables. These cables have increased isolation thickness to withstand voltage spikes that can occur in low-voltage frequency drives, and to withstand accelerated aging of the insulation material due to higher frequencies. The tinned copper wire braiding offers excellent EMI protection and mechanical protection. Special types available on request.
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 111 mm
Bending radius during installation: 195 mm
Binde: Polyester tape
Capacity: 61 nF/km
Conductor AC resistance at maximum continuous temperature: 0.49 Ohm/km
Conductor dc resistance @ 20°c: 0.387 Ohm/km
Construction outer shield: tinned copper braiding
Core identification: HD 308 S2
Core lay-up: Concentric layers
Diameter conductor: 12.96 mm
Diameter over braiding: 24.5 mm
Diameter shield wires: 0.3 mm
Inductance: 0.212 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 50 mm²
Nominal outer sheath thickness: 1.7 mm
Reel à 1: (16501 / 8713182080228)
Reel à 500: (16501H X 500/20 / 8713182080211)
Screening: Yes
Series: Shipboard cable
Shape of conductor: Sector-shaped
Sheath marking: {Length} TKF - 3X50 svs - 1,8/3 kV - CS 90 - mbzh - MarineLine YOZp HALOGEN FREE {Batch}
Standardization conductor material: IEC 60228
Standardization sheath material: IEC 60092-360
Tensile load: 2250 N
Indicative image NULL
Category Cable
Type MarineLine YOZp 1,8/3 kV 3 x 50 svs
Uteco Code 1-54-50-16-50-1
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16501
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16501
Description: 3 x 50 svs
Cores: 3
Approx. Outer diameter: 27.8 mm
Net weight (k: 1,861 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Cu
Conductor category: Class 2 = stranded
Core insulation: XLPE (VPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, in movement: -20 / 70 °C
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1.8 kV
Nominal voltage U: 3 kV
Test voltage: 6500 V
Colour outer sheath: Black
Product group: Shipboard low voltage cable
Application: Special Frequency Drive cables. These cables have increased isolation thickness to withstand voltage spikes that can occur in low-voltage frequency drives, and to withstand accelerated aging of the insulation material due to higher frequencies. The tinned copper wire braiding offers excellent EMI protection and mechanical protection. Special types available on request.
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 111 mm
Bending radius during installation: 195 mm
Binde: Polyester tape
Capacity: 61 nF/km
Conductor AC resistance at maximum continuous temperature: 0.49 Ohm/km
Conductor dc resistance @ 20°c: 0.387 Ohm/km
Construction outer shield: tinned copper braiding
Core identification: HD 308 S2
Core lay-up: Concentric layers
Diameter conductor: 12.96 mm
Diameter over braiding: 24.5 mm
Diameter shield wires: 0.3 mm
Inductance: 0.212 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 50 mm²
Nominal outer sheath thickness: 1.7 mm
Reel à 1: (16501 / 8713182080228)
Reel à 500: (16501H X 500/20 / 8713182080211)
Screening: Yes
Series: Shipboard cable
Shape of conductor: Sector-shaped
Sheath marking: {Length} TKF - 3X50 svs - 1,8/3 kV - CS 90 - mbzh - MarineLine YOZp HALOGEN FREE {Batch}
Standardization conductor material: IEC 60228
Standardization sheath material: IEC 60092-360
Tensile load: 2250 N
Indicative image NULL
Category Cable
Type MarineLine YOZp 1,8/3 kV 3 x 70 svs
Uteco Code 1-54-50-16-50-2
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16502
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16502
Description: 3 x 70 svs
Cores: 3
Approx. Outer diameter: 31.8 mm
Net weight (k: 2,536 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Cu
Conductor category: Class 2 = stranded
Core insulation: XLPE (VPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, in movement: -20 / 70 °C
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1.8 kV
Nominal voltage U: 3 kV
Test voltage: 6500 V
Colour outer sheath: Black
Product group: Shipboard low voltage cable
Application: Special Frequency Drive cables. These cables have increased isolation thickness to withstand voltage spikes that can occur in low-voltage frequency drives, and to withstand accelerated aging of the insulation material due to higher frequencies. The tinned copper wire braiding offers excellent EMI protection and mechanical protection. Special types available on request.
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 127 mm
Bending radius during installation: 223 mm
Binde: Polyester tape
Capacity: 73 nF/km
Conductor AC resistance at maximum continuous temperature: 0.34 Ohm/km
Conductor dc resistance @ 20°c: 0.268 Ohm/km
Construction outer shield: tinned copper braiding
Core identification: HD 308 S2
Core lay-up: Concentric layers
Diameter conductor: 14.96 mm
Diameter over braiding: 28.1 mm
Diameter shield wires: 0.3 mm
Inductance: 0.2 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 70 mm²
Nominal outer sheath thickness: 1.9 mm
Reel à 1: (16502 / 8713182080242)
Reel à 500: (16502H X 500/20 / 8713182080235)
Screening: Yes
Series: Shipboard cable
Shape of conductor: Sector-shaped
Sheath marking: {Length} TKF - 3X70 svs - 1,8/3 kV - CS 90 - mbzh - MarineLine YOZp HALOGEN FREE {Batch}
Standardization conductor material: IEC 60228
Standardization sheath material: IEC 60092-360
Tensile load: 3150 N
Indicative image NULL
Category Cable
Type MarineLine YOZp 1,8/3 kV 3 x 70 svs
Uteco Code 1-54-50-16-50-2
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16502
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16502
Description: 3 x 70 svs
Cores: 3
Approx. Outer diameter: 31.8 mm
Net weight (k: 2,536 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Cu
Conductor category: Class 2 = stranded
Core insulation: XLPE (VPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, in movement: -20 / 70 °C
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1.8 kV
Nominal voltage U: 3 kV
Test voltage: 6500 V
Colour outer sheath: Black
Product group: Shipboard low voltage cable
Application: Special Frequency Drive cables. These cables have increased isolation thickness to withstand voltage spikes that can occur in low-voltage frequency drives, and to withstand accelerated aging of the insulation material due to higher frequencies. The tinned copper wire braiding offers excellent EMI protection and mechanical protection. Special types available on request.
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 127 mm
Bending radius during installation: 223 mm
Binde: Polyester tape
Capacity: 73 nF/km
Conductor AC resistance at maximum continuous temperature: 0.34 Ohm/km
Conductor dc resistance @ 20°c: 0.268 Ohm/km
Construction outer shield: tinned copper braiding
Core identification: HD 308 S2
Core lay-up: Concentric layers
Diameter conductor: 14.96 mm
Diameter over braiding: 28.1 mm
Diameter shield wires: 0.3 mm
Inductance: 0.2 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 70 mm²
Nominal outer sheath thickness: 1.9 mm
Reel à 1: (16502 / 8713182080242)
Reel à 500: (16502H X 500/20 / 8713182080235)
Screening: Yes
Series: Shipboard cable
Shape of conductor: Sector-shaped
Sheath marking: {Length} TKF - 3X70 svs - 1,8/3 kV - CS 90 - mbzh - MarineLine YOZp HALOGEN FREE {Batch}
Standardization conductor material: IEC 60228
Standardization sheath material: IEC 60092-360
Tensile load: 3150 N
Indicative image NULL
Category Cable
Type MarineLine YOZp 1,8/3 kV 3 x 95 svs
Uteco Code 1-54-50-16-50-3
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16503
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16503
Description: 3 x 95 svs
Cores: 3
Approx. Outer diameter: 36.4 mm
Net weight (k: 3,498 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Cu
Conductor category: Class 2 = stranded
Core insulation: XLPE (VPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, in movement: -20 / 70 °C
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1.8 kV
Nominal voltage U: 3 kV
Test voltage: 6500 V
Colour outer sheath: Black
Product group: Shipboard low voltage cable
Application: Special Frequency Drive cables. These cables have increased isolation thickness to withstand voltage spikes that can occur in low-voltage frequency drives, and to withstand accelerated aging of the insulation material due to higher frequencies. The tinned copper wire braiding offers excellent EMI protection and mechanical protection. Special types available on request.
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 146 mm
Bending radius during installation: 255 mm
Binde: Polyester tape
Capacity: 83 nF/km
Conductor AC resistance at maximum continuous temperature: 0.24 Ohm/km
Conductor dc resistance @ 20°c: 0.193 Ohm/km
Construction outer shield: tinned copper braiding
Core identification: HD 308 S2
Core lay-up: Concentric layers
Diameter conductor: 16.96 mm
Diameter over braiding: 32.3 mm
Diameter shield wires: 0.4 mm
Inductance: 0.198 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 95 mm²
Nominal outer sheath thickness: 2.1 mm
Reel à 1: (16503 / 8713182080266)
Reel à 500: (16503H X 500/20 / 8713182080259)
Screening: Yes
Series: Shipboard cable
Shape of conductor: Sector-shaped
Sheath marking: {Length} TKF - 3X95 svs - 1,8/3 kV - CS 90 - mbzh - MarineLine YOZp HALOGEN FREE {Batch}
Standardization conductor material: IEC 60228
Standardization sheath material: IEC 60092-360
Tensile load: 4275 N
Indicative image NULL
Category Cable
Type MarineLine YOZp 1,8/3 kV 3 x 95 svs
Uteco Code 1-54-50-16-50-3
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16503
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16503
Description: 3 x 95 svs
Cores: 3
Approx. Outer diameter: 36.4 mm
Net weight (k: 3,498 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Cu
Conductor category: Class 2 = stranded
Core insulation: XLPE (VPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, in movement: -20 / 70 °C
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1.8 kV
Nominal voltage U: 3 kV
Test voltage: 6500 V
Colour outer sheath: Black
Product group: Shipboard low voltage cable
Application: Special Frequency Drive cables. These cables have increased isolation thickness to withstand voltage spikes that can occur in low-voltage frequency drives, and to withstand accelerated aging of the insulation material due to higher frequencies. The tinned copper wire braiding offers excellent EMI protection and mechanical protection. Special types available on request.
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 146 mm
Bending radius during installation: 255 mm
Binde: Polyester tape
Capacity: 83 nF/km
Conductor AC resistance at maximum continuous temperature: 0.24 Ohm/km
Conductor dc resistance @ 20°c: 0.193 Ohm/km
Construction outer shield: tinned copper braiding
Core identification: HD 308 S2
Core lay-up: Concentric layers
Diameter conductor: 16.96 mm
Diameter over braiding: 32.3 mm
Diameter shield wires: 0.4 mm
Inductance: 0.198 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 95 mm²
Nominal outer sheath thickness: 2.1 mm
Reel à 1: (16503 / 8713182080266)
Reel à 500: (16503H X 500/20 / 8713182080259)
Screening: Yes
Series: Shipboard cable
Shape of conductor: Sector-shaped
Sheath marking: {Length} TKF - 3X95 svs - 1,8/3 kV - CS 90 - mbzh - MarineLine YOZp HALOGEN FREE {Batch}
Standardization conductor material: IEC 60228
Standardization sheath material: IEC 60092-360
Tensile load: 4275 N
Indicative image 1-54-50-16-54-1
Category Cable
Type MarineLine YOZp EMC 0,6/1 kV 12 G 2,5 mm2
Uteco Code 1-54-50-16-54-1
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16541
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16541
Description: 12 G 2,5 mm²
Cores: 12
Approx. Outer diameter: 17,3 mm
Core Colors: Green/Yellow - Black, with white printed numbers
Net weight (k: 0,543 kg/m
Type: MarineLine YOZp EMC 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Low voltage shipboard power cables with enhanced EMC properties for use in sensitive EMC areas and suitable for Variable Frequency Drive applications. Enhanced shielding properties due to optimized tinned copper wire braid in combination with 100% foil-screen coverage.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 70 mm
Bending radius during installation: 123 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 9,3 Ohm/km
Conductor dc resistance @ 20°c: 7,41 Ohm/km
Construction outer shield: EMC-screen consists of Cu/PET-tape and tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 1,56 mm
Diameter over braiding: 14,7 mm
Diameter shield wires: 0,3 mm
Inductance: 0,279 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 2,5 mm²
Nominal outer sheath thickness: 1,4 mm
Protective conductor: Yes
Reel à 500: (16541H X 500/20 / 8713182262211)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp EMC 0,6/1 kV - 12G2,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 450 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Designed for situations that need Electro-Magnetic Interference to be limited to the minimum • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armoring • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16541 / 8713182262204)
Indicative image 1-54-50-16-54-1
Category Cable
Type MarineLine YOZp EMC 0,6/1 kV 12 G 2,5 mm2
Uteco Code 1-54-50-16-54-1
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16541
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16541
Description: 12 G 2,5 mm²
Cores: 12
Approx. Outer diameter: 17,3 mm
Core Colors: Green/Yellow - Black, with white printed numbers
Net weight (k: 0,543 kg/m
Type: MarineLine YOZp EMC 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Low voltage shipboard power cables with enhanced EMC properties for use in sensitive EMC areas and suitable for Variable Frequency Drive applications. Enhanced shielding properties due to optimized tinned copper wire braid in combination with 100% foil-screen coverage.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 70 mm
Bending radius during installation: 123 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 9,3 Ohm/km
Conductor dc resistance @ 20°c: 7,41 Ohm/km
Construction outer shield: EMC-screen consists of Cu/PET-tape and tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 1,56 mm
Diameter over braiding: 14,7 mm
Diameter shield wires: 0,3 mm
Inductance: 0,279 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 2,5 mm²
Nominal outer sheath thickness: 1,4 mm
Protective conductor: Yes
Reel à 500: (16541H X 500/20 / 8713182262211)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp EMC 0,6/1 kV - 12G2,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 450 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Designed for situations that need Electro-Magnetic Interference to be limited to the minimum • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armoring • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16541 / 8713182262204)
Indicative image 1-54-50-17-37-8
Category Cable
Type MarineLine YOZp EMC 0,6/1 kV 3 x 10 mm2 + 3 G 4 mm2
Uteco Code 1-54-50-17-37-8
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 17378
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 17378
Description: 3 x 10 mm² + 3 G 4 mm²
Cores: 3
Approx. Outer diameter: 17,9 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,629 kg/m
Type: MarineLine YOZp EMC 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Low voltage shipboard power cables with enhanced EMC properties for use in sensitive EMC areas and suitable for Variable Frequency Drive applications. Enhanced shielding properties due to optimized tinned copper wire braid in combination with 100% foil-screen coverage.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Auxiliary conductor(s): Yes
Bending radius after installation: 144 mm
Bending radius during installation: 215 mm
Binde: Polyester tape
Capacity: 55 nF/km
Conductor AC resistance at maximum continuous temperature: 2,3 Ohm/km
Conductor dc resistance @ 20°c: 1,83 Ohm/km
Construction outer shield: EMC-screen consists of Cu/PET-tape and tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 3,85 mm
Diameter over braiding: 15,1 mm
Diameter shield wires: 0,3 mm
Inductance: 0,244 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 10 mm²
Nominal outer sheath thickness: 1,4 mm
Reel à 1000: (17378H X 1000 / 8713182278045)
Reel à 500: (17378H X 500/20 / 8713182278052)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp EMC 0,6/1 kV - 3x10 + 3G4 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 630 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Designed for situations that need Electro-Magnetic Interference to be limited to the minimum • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armoring • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Nominal cross section pilo: 4 mm²
Number of pilo: 3
Standard trade article: (17378 / 8713182278038)
Indicative image 1-54-50-17-37-8
Category Cable
Type MarineLine YOZp EMC 0,6/1 kV 3 x 10 mm2 + 3 G 4 mm2
Uteco Code 1-54-50-17-37-8
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 17378
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 17378
Description: 3 x 10 mm² + 3 G 4 mm²
Cores: 3
Approx. Outer diameter: 17,9 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,629 kg/m
Type: MarineLine YOZp EMC 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Low voltage shipboard power cables with enhanced EMC properties for use in sensitive EMC areas and suitable for Variable Frequency Drive applications. Enhanced shielding properties due to optimized tinned copper wire braid in combination with 100% foil-screen coverage.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Auxiliary conductor(s): Yes
Bending radius after installation: 144 mm
Bending radius during installation: 215 mm
Binde: Polyester tape
Capacity: 55 nF/km
Conductor AC resistance at maximum continuous temperature: 2,3 Ohm/km
Conductor dc resistance @ 20°c: 1,83 Ohm/km
Construction outer shield: EMC-screen consists of Cu/PET-tape and tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 3,85 mm
Diameter over braiding: 15,1 mm
Diameter shield wires: 0,3 mm
Inductance: 0,244 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 10 mm²
Nominal outer sheath thickness: 1,4 mm
Reel à 1000: (17378H X 1000 / 8713182278045)
Reel à 500: (17378H X 500/20 / 8713182278052)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp EMC 0,6/1 kV - 3x10 + 3G4 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 630 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Designed for situations that need Electro-Magnetic Interference to be limited to the minimum • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armoring • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Nominal cross section pilo: 4 mm²
Number of pilo: 3
Standard trade article: (17378 / 8713182278038)
Indicative image 1-54-50-17-34-8
Category Cable
Type MarineLine YOZp EMC 0,6/1 kV 3 x 16 mm2
Uteco Code 1-54-50-17-34-8
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 17348
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 17348
Description: 3 x 16 mm²
Cores: 3
Approx. Outer diameter: 17 mm
Core Colors: Brown - Black - Grey
Net weight (k: 0,637 kg/m
Type: MarineLine YOZp EMC 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Low voltage shipboard power cables with enhanced EMC properties for use in sensitive EMC areas and suitable for Variable Frequency Drive applications. Enhanced shielding properties due to optimized tinned copper wire braid in combination with 100% foil-screen coverage.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 70 mm
Bending radius during installation: 120 mm
Binde: Polyester tape
Capacity: 61 nF/km
Conductor AC resistance at maximum continuous temperature: 1,4 Ohm/km
Conductor dc resistance @ 20°c: 1,15 Ohm/km
Construction outer shield: EMC-screen consists of Cu/PET-tape and tinned copper braiding
Core identification: Colour
Diameter conductor: 4,85 mm
Diameter over braiding: 14,2 mm
Diameter shield wires: 0,3 mm
Inductance: 0,227 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 16 mm²
Nominal outer sheath thickness: 1,4 mm
Reel à 1000: (17348H X 1000/30 / 8713182249403)
Reel à 500: (17348H X 500/20 / 8713182249410)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp EMC 0,6/1 kV - 3x16 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 720 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Designed for situations that need Electro-Magnetic Interference to be limited to the minimum • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armoring • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (17348 / 8713182249397)
Indicative image 1-54-50-17-34-8
Category Cable
Type MarineLine YOZp EMC 0,6/1 kV 3 x 16 mm2
Uteco Code 1-54-50-17-34-8
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 17348
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 17348
Description: 3 x 16 mm²
Cores: 3
Approx. Outer diameter: 17 mm
Core Colors: Brown - Black - Grey
Net weight (k: 0,637 kg/m
Type: MarineLine YOZp EMC 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Low voltage shipboard power cables with enhanced EMC properties for use in sensitive EMC areas and suitable for Variable Frequency Drive applications. Enhanced shielding properties due to optimized tinned copper wire braid in combination with 100% foil-screen coverage.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 70 mm
Bending radius during installation: 120 mm
Binde: Polyester tape
Capacity: 61 nF/km
Conductor AC resistance at maximum continuous temperature: 1,4 Ohm/km
Conductor dc resistance @ 20°c: 1,15 Ohm/km
Construction outer shield: EMC-screen consists of Cu/PET-tape and tinned copper braiding
Core identification: Colour
Diameter conductor: 4,85 mm
Diameter over braiding: 14,2 mm
Diameter shield wires: 0,3 mm
Inductance: 0,227 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 16 mm²
Nominal outer sheath thickness: 1,4 mm
Reel à 1000: (17348H X 1000/30 / 8713182249403)
Reel à 500: (17348H X 500/20 / 8713182249410)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp EMC 0,6/1 kV - 3x16 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 720 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Designed for situations that need Electro-Magnetic Interference to be limited to the minimum • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armoring • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (17348 / 8713182249397)
Indicative image 1-54-50-17-17-6
Category Cable
Type MarineLine YOZp EMC 0,6/1 kV 3 x 16 mm2 + 3 G 6 mm2
Uteco Code 1-54-50-17-17-6
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 17176
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 17176
Description: 3 x 16 mm² + 3 G 6 mm²
Cores: 3
Approx. Outer diameter: 20,4 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,875 kg/m
Type: MarineLine YOZp EMC 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Low voltage shipboard power cables with enhanced EMC properties for use in sensitive EMC areas and suitable for Variable Frequency Drive applications. Enhanced shielding properties due to optimized tinned copper wire braid in combination with 100% foil-screen coverage.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 164 mm
Bending radius during installation: 245 mm
Binde: Polyester tape
Capacity: 61 nF/km
Conductor AC resistance at maximum continuous temperature: 1,4 Ohm/km
Conductor dc resistance @ 20°c: 1,15 Ohm/km
Construction outer shield: EMC-screen consists of Cu/PET-tape and tinned copper braiding
Core identification: Colour
Diameter conductor: 4,85 mm
Diameter over braiding: 17,4 mm
Diameter shield wires: 0,3 mm
Inductance: 0,227 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 16 mm²
Nominal outer sheath thickness: 1,5 mm
Protective conductor: Yes
Reel à 1000: (17176H X 1000/30 / 8713182254612)
Reel à 500: (17176H X 500/20 / 8713182254629)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp EMC 0,6/1 kV - 3x16 + 3G6 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 990 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Designed for situations that need Electro-Magnetic Interference to be limited to the minimum • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armoring • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Colours of auxiliary wire insulation: Green/Yellow
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Nominal cross section pe conductor: 6 mm²
Number of pe conductors: 3
Standard trade article: (17176 / 8713182254605)
Indicative image 1-54-50-17-17-6
Category Cable
Type MarineLine YOZp EMC 0,6/1 kV 3 x 16 mm2 + 3 G 6 mm2
Uteco Code 1-54-50-17-17-6
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 17176
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 17176
Description: 3 x 16 mm² + 3 G 6 mm²
Cores: 3
Approx. Outer diameter: 20,4 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,875 kg/m
Type: MarineLine YOZp EMC 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Low voltage shipboard power cables with enhanced EMC properties for use in sensitive EMC areas and suitable for Variable Frequency Drive applications. Enhanced shielding properties due to optimized tinned copper wire braid in combination with 100% foil-screen coverage.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 164 mm
Bending radius during installation: 245 mm
Binde: Polyester tape
Capacity: 61 nF/km
Conductor AC resistance at maximum continuous temperature: 1,4 Ohm/km
Conductor dc resistance @ 20°c: 1,15 Ohm/km
Construction outer shield: EMC-screen consists of Cu/PET-tape and tinned copper braiding
Core identification: Colour
Diameter conductor: 4,85 mm
Diameter over braiding: 17,4 mm
Diameter shield wires: 0,3 mm
Inductance: 0,227 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 16 mm²
Nominal outer sheath thickness: 1,5 mm
Protective conductor: Yes
Reel à 1000: (17176H X 1000/30 / 8713182254612)
Reel à 500: (17176H X 500/20 / 8713182254629)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp EMC 0,6/1 kV - 3x16 + 3G6 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 990 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Designed for situations that need Electro-Magnetic Interference to be limited to the minimum • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armoring • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Colours of auxiliary wire insulation: Green/Yellow
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Nominal cross section pe conductor: 6 mm²
Number of pe conductors: 3
Standard trade article: (17176 / 8713182254605)
Indicative image 1-54-50-17-19-3
Category Cable
Type MarineLine YOZp EMC 0,6/1 kV 3x10 mm2
Uteco Code 1-54-50-17-19-3
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 17193
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 17193
Description: 3 x 10 mm²
Cores: 3
Approx. Outer diameter: 14,9 mm
Core Colors: Brown - Black - Grey
Net weight (k: 0,46 kg/m
Type: MarineLine YOZp EMC 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Low voltage shipboard power cables with enhanced EMC properties for use in sensitive EMC areas and suitable for Variable Frequency Drive applications. Enhanced shielding properties due to optimized tinned copper wire braid in combination with 100% foil-screen coverage.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 60 mm
Bending radius during installation: 104 mm
Binde: Polyester tape
Capacity: 55 nF/km
Conductor AC resistance at maximum continuous temperature: 2,3 Ohm/km
Conductor dc resistance @ 20°c: 1,83 Ohm/km
Construction outer shield: EMC-screen consists of Cu/PET-tape and tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 3,85 mm
Diameter over braiding: 12,2 mm
Diameter shield wires: 0,3 mm
Inductance: 0,244 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 10 mm²
Nominal outer sheath thickness: 1,3 mm
Reel à 1000: (17193H X 1000 / 8713182205805)
Reel à 500: (17193H X 500/20 / 8713182205812)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp EMC 0,6/1 kV - 3x10 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 450 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Designed for situations that need Electro-Magnetic Interference to be limited to the minimum • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armoring • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (17193 / 8713182205829)