Indicative image 1-54-50-16-12-8
Category Cable
Type MarineLine YOZp 0,6/1 kV 7x2,5 mm2
Uteco Code 1-54-50-16-12-8
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16128
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16128
Description: 7 x 2,5 mm²
Cores: 7
Approx. Outer diameter: 12,9 mm
Core Colors: Black, with white printed numbers
Net weight (k: 0,306 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 52 mm
Bending radius during installation: 91 mm
Binde: Polyester tape
Capacity: 35 nF/km
Conductor AC resistance at maximum continuous temperature: 9,3 Ohm/km
Conductor dc resistance @ 20°c: 7,41 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 2,04 mm
Diameter over braiding: 10,5 mm
Diameter shield wires: 0,2 mm
Inductance: 0,279 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 2,5 mm²
Nominal outer sheath thickness: 1,2 mm
Reel à 1000: (16128H X 1000/30 / 8713182049072)
Reel à 500: (16128H X 500/20 / 8713182049058)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 7x2,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 263 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (16128 / 8713182049065)
Indicative image 1-54-50-16-11-7
Category Cable
Type MarineLine YOZp 0,6/1 kV 8x1,5 mm2
Uteco Code 1-54-50-16-11-7
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16117
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 16117
Description: 8 x 1,5 mm²
Cores: 8
Approx. Outer diameter: 12,7 mm
Core Colors: Black, with white printed numbers
Net weight (k: 0,274 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 51 mm
Bending radius during installation: 89 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 1,56 mm
Diameter over braiding: 10,3 mm
Diameter shield wires: 0,2 mm
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,2 mm
Reel à 1000: (16117H X 1000/30 / 8713182048631)
Reel à 500: (16117H X 500/20 / 8713182048617)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 8x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 180 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (16117 / 8713182048624)
Indicative image 1-54-50-16-11-7
Category Cable
Type MarineLine YOZp 0,6/1 kV 8x1,5 mm2
Uteco Code 1-54-50-16-11-7
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16117
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 16117
Description: 8 x 1,5 mm²
Cores: 8
Approx. Outer diameter: 12,7 mm
Core Colors: Black, with white printed numbers
Net weight (k: 0,274 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 51 mm
Bending radius during installation: 89 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 1,56 mm
Diameter over braiding: 10,3 mm
Diameter shield wires: 0,2 mm
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,2 mm
Reel à 1000: (16117H X 1000/30 / 8713182048631)
Reel à 500: (16117H X 500/20 / 8713182048617)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 8x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 180 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (16117 / 8713182048624)
Indicative image 1-54-50-16-49-6
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 120 mm2
Uteco Code 1-54-50-16-49-6
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16496
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16496
Description: 1 x 120 mm²
Cores: 1
Approx. Outer diameter: 22,6 mm
Core Colors: Black
Net weight (k: 1,413 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 91 mm
Bending radius during installation: 159 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,19 Ohm/km
Conductor dc resistance @ 20°c: 0,153 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 14,2 mm
Diameter over braiding: 19,5 mm
Diameter shield wires: 0,3 mm
Inductance: 0,192 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 120 mm²
Nominal outer sheath thickness: 1,6 mm
Reel à 500: (16496H X 500/20 / 8713182080112)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x120 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 1.800 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16496 / 8713182080129)
Indicative image 1-54-50-16-49-6
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 120 mm2
Uteco Code 1-54-50-16-49-6
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16496
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16496
Description: 1 x 120 mm²
Cores: 1
Approx. Outer diameter: 22,6 mm
Core Colors: Black
Net weight (k: 1,413 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 91 mm
Bending radius during installation: 159 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,19 Ohm/km
Conductor dc resistance @ 20°c: 0,153 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 14,2 mm
Diameter over braiding: 19,5 mm
Diameter shield wires: 0,3 mm
Inductance: 0,192 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 120 mm²
Nominal outer sheath thickness: 1,6 mm
Reel à 500: (16496H X 500/20 / 8713182080112)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x120 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 1.800 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16496 / 8713182080129)
Indicative image 1-54-50-16-49-7
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 150 mm2
Uteco Code 1-54-50-16-49-7
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16497
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16497
Description: 1 x 150 mm²
Cores: 1
Approx. Outer diameter: 24,1 mm
Core Colors: Black
Net weight (k: 1,669 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 97 mm
Bending radius during installation: 169 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,16 Ohm/km
Conductor dc resistance @ 20°c: 0,124 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 15,75 mm
Diameter over braiding: 21,1 mm
Diameter shield wires: 0,3 mm
Inductance: 0,193 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 150 mm²
Nominal outer sheath thickness: 1,6 mm
Reel à 500: (16497H X 500/20 / 8713182080136)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x150 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 2.250 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16497 / 8713182080143)
Indicative image 1-54-50-16-49-7
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 150 mm2
Uteco Code 1-54-50-16-49-7
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16497
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16497
Description: 1 x 150 mm²
Cores: 1
Approx. Outer diameter: 24,1 mm
Core Colors: Black
Net weight (k: 1,669 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 97 mm
Bending radius during installation: 169 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,16 Ohm/km
Conductor dc resistance @ 20°c: 0,124 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 15,75 mm
Diameter over braiding: 21,1 mm
Diameter shield wires: 0,3 mm
Inductance: 0,193 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 150 mm²
Nominal outer sheath thickness: 1,6 mm
Reel à 500: (16497H X 500/20 / 8713182080136)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x150 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 2.250 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16497 / 8713182080143)
Indicative image 1-54-50-16-49-8
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 185 mm2
Uteco Code 1-54-50-16-49-8
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16498
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16498
Description: 1 x 185 mm²
Cores: 1
Approx. Outer diameter: 26,2 mm
Core Colors: Black
Net weight (k: 1,945 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 105 mm
Bending radius during installation: 185 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,124 Ohm/km
Conductor dc resistance @ 20°c: 0,0991 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 17,64 mm
Diameter over braiding: 23 mm
Diameter shield wires: 0,3 mm
Inductance: 0,192 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 185 mm²
Nominal outer sheath thickness: 1,7 mm
Reel à 500: (16498H X 500/20 / 8713182080150)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x185 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 2.775 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16498 / 8713182080167)
Indicative image 1-54-50-16-49-8
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 185 mm2
Uteco Code 1-54-50-16-49-8
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16498
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16498
Description: 1 x 185 mm²
Cores: 1
Approx. Outer diameter: 26,2 mm
Core Colors: Black
Net weight (k: 1,945 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 105 mm
Bending radius during installation: 185 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,124 Ohm/km
Conductor dc resistance @ 20°c: 0,0991 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 17,64 mm
Diameter over braiding: 23 mm
Diameter shield wires: 0,3 mm
Inductance: 0,192 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 185 mm²
Nominal outer sheath thickness: 1,7 mm
Reel à 500: (16498H X 500/20 / 8713182080150)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x185 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 2.775 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16498 / 8713182080167)
Indicative image 1-54-50-16-49-9
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 240 mm2
Uteco Code 1-54-50-16-49-9
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16499
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16499
Description: 1 x 240 mm²
Cores: 1
Approx. Outer diameter: 29,1 mm
Core Colors: Black
Net weight (k: 2,616 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 117 mm
Bending radius during installation: 204 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,095 Ohm/km
Conductor dc resistance @ 20°c: 0,0754 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 20,1 mm
Diameter over braiding: 25,6 mm
Diameter shield wires: 0,3 mm
Inductance: 0,19 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 240 mm²
Nominal outer sheath thickness: 1,8 mm
Reel à 500: (16499H X 500/20 / 8713182080174)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x240 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 3.600 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16499 / 8713182080181)
Indicative image 1-54-50-16-49-9
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 240 mm2
Uteco Code 1-54-50-16-49-9
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16499
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16499
Description: 1 x 240 mm²
Cores: 1
Approx. Outer diameter: 29,1 mm
Core Colors: Black
Net weight (k: 2,616 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 117 mm
Bending radius during installation: 204 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,095 Ohm/km
Conductor dc resistance @ 20°c: 0,0754 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 20,1 mm
Diameter over braiding: 25,6 mm
Diameter shield wires: 0,3 mm
Inductance: 0,19 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 240 mm²
Nominal outer sheath thickness: 1,8 mm
Reel à 500: (16499H X 500/20 / 8713182080174)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x240 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 3.600 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16499 / 8713182080181)
Indicative image 1-54-50-16-49-2
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 35 mm2
Uteco Code 1-54-50-16-49-2
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16492
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16492
Description: 1 x 35 mm²
Cores: 1
Approx. Outer diameter: 15,4 mm
Core Colors: Black
Net weight (k: 0,522 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 62 mm
Bending radius during installation: 109 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,66 Ohm/km
Conductor dc resistance @ 20°c: 0,524 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 7,5 mm
Diameter over braiding: 13 mm
Diameter shield wires: 0,3 mm
Inductance: 0,211 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 35 mm²
Nominal outer sheath thickness: 1,3 mm
Reel à 500: (16492H X 500/20 / 8713182080037)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x35 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 525 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16492 / 8713182080044)
Indicative image 1-54-50-16-49-2
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 35 mm2
Uteco Code 1-54-50-16-49-2
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16492
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16492
Description: 1 x 35 mm²
Cores: 1
Approx. Outer diameter: 15,4 mm
Core Colors: Black
Net weight (k: 0,522 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 62 mm
Bending radius during installation: 109 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,66 Ohm/km
Conductor dc resistance @ 20°c: 0,524 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 7,5 mm
Diameter over braiding: 13 mm
Diameter shield wires: 0,3 mm
Inductance: 0,211 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 35 mm²
Nominal outer sheath thickness: 1,3 mm
Reel à 500: (16492H X 500/20 / 8713182080037)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x35 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 525 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16492 / 8713182080044)
Indicative image 1-54-50-16-49-3
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 50 mm2
Uteco Code 1-54-50-16-49-3
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16493
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16493
Description: 1 x 50 mm²
Cores: 1
Approx. Outer diameter: 16,9 mm
Core Colors: Black
Net weight (k: 0,655 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 68 mm
Bending radius during installation: 119 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,49 Ohm/km
Conductor dc resistance @ 20°c: 0,387 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 8,9 mm
Diameter over braiding: 14,2 mm
Diameter shield wires: 0,3 mm
Inductance: 0,212 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 50 mm²
Nominal outer sheath thickness: 1,4 mm
Reel à 500: (16493H X 500/20 / 8713182080051)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x50 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 750 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16493 / 8713182080068)
Indicative image 1-54-50-16-49-3
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 50 mm2
Uteco Code 1-54-50-16-49-3
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16493
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16493
Description: 1 x 50 mm²
Cores: 1
Approx. Outer diameter: 16,9 mm
Core Colors: Black
Net weight (k: 0,655 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 68 mm
Bending radius during installation: 119 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,49 Ohm/km
Conductor dc resistance @ 20°c: 0,387 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 8,9 mm
Diameter over braiding: 14,2 mm
Diameter shield wires: 0,3 mm
Inductance: 0,212 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 50 mm²
Nominal outer sheath thickness: 1,4 mm
Reel à 500: (16493H X 500/20 / 8713182080051)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x50 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 750 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16493 / 8713182080068)
Indicative image 1-54-50-16-49-4
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 70 mm2
Uteco Code 1-54-50-16-49-4
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16494
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16494
Description: 1 x 70 mm²
Cores: 1
Approx. Outer diameter: 18,6 mm
Core Colors: Black
Net weight (k: 0,865 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 75 mm
Bending radius during installation: 131 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,34 Ohm/km
Conductor dc resistance @ 20°c: 0,268 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 10,65 mm
Diameter over braiding: 16 mm
Diameter shield wires: 0,3 mm
Inductance: 0,2 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 70 mm²
Nominal outer sheath thickness: 1,4 mm
Reel à 500: (16494H X 500/20 / 8713182080075)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x70 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 1.050 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16494 / 8713182080082)
Indicative image 1-54-50-16-49-4
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 70 mm2
Uteco Code 1-54-50-16-49-4
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16494
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16494
Description: 1 x 70 mm²
Cores: 1
Approx. Outer diameter: 18,6 mm
Core Colors: Black
Net weight (k: 0,865 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 75 mm
Bending radius during installation: 131 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,34 Ohm/km
Conductor dc resistance @ 20°c: 0,268 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 10,65 mm
Diameter over braiding: 16 mm
Diameter shield wires: 0,3 mm
Inductance: 0,2 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 70 mm²
Nominal outer sheath thickness: 1,4 mm
Reel à 500: (16494H X 500/20 / 8713182080075)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x70 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 1.050 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16494 / 8713182080082)
Indicative image 1-54-50-16-49-5
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 95 mm2
Uteco Code 1-54-50-16-49-5
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16495
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16495
Description: 1 x 95 mm²
Cores: 1
Approx. Outer diameter: 20,7 mm
Core Colors: Black
Net weight (k: 1,133 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 83 mm
Bending radius during installation: 146 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,24 Ohm/km
Conductor dc resistance @ 20°c: 0,193 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 12,5 mm
Diameter over braiding: 17,8 mm
Diameter shield wires: 0,3 mm
Inductance: 0,198 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 95 mm²
Nominal outer sheath thickness: 1,5 mm
Reel à 500: (16495H X 500/20 / 8713182080099)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x95 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 1.425 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16495 / 8713182080105)
Indicative image 1-54-50-16-49-5
Category Cable
Type MarineLine YOZp 1,8/3 kV 1 x 95 mm2
Uteco Code 1-54-50-16-49-5
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16495
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16495
Description: 1 x 95 mm²
Cores: 1
Approx. Outer diameter: 20,7 mm
Core Colors: Black
Net weight (k: 1,133 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1,8 kV
Nominal voltage U: 3 kV
Test voltage: 6,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 83 mm
Bending radius during installation: 146 mm
Binde: FRNC filler
Conductor AC resistance at maximum continuous temperature: 0,24 Ohm/km
Conductor dc resistance @ 20°c: 0,193 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 12,5 mm
Diameter over braiding: 17,8 mm
Diameter shield wires: 0,3 mm
Inductance: 0,198 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 95 mm²
Nominal outer sheath thickness: 1,5 mm
Reel à 500: (16495H X 500/20 / 8713182080099)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 1,8/3 kV - 1x95 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 1.425 N
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request
Conductor coding in accordance with hd 308 s2: Yes
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (16495 / 8713182080105)
Indicative image NULL
Category Cable
Type MarineLine YOZp 1,8/3 kV 3 x 150 svs
Uteco Code 1-54-50-16-50-5
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16505
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16505
Description: 3 x 150 svs
Cores: 3
Approx. Outer diameter: 42.1 mm
Net weight (k: 5,083 kg/m
Type: MarineLine YOZp 1,8/3 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Cu
Conductor category: Class 2 = stranded
Core insulation: XLPE (VPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, in movement: -20 / 70 °C
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 1.8 kV
Nominal voltage U: 3 kV
Test voltage: 6500 V
Colour outer sheath: Black
Product group: Shipboard low voltage cable
Application: Special Frequency Drive cables. These cables have increased isolation thickness to withstand voltage spikes that can occur in low-voltage frequency drives, and to withstand accelerated aging of the insulation material due to higher frequencies. The tinned copper wire braiding offers excellent EMI protection and mechanical protection. Special types available on request.
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 168 mm
Bending radius during installation: 295 mm
Binde: Polyester tape
Capacity: 90 nF/km
Conductor AC resistance at maximum continuous temperature: 0.16 Ohm/km
Conductor dc resistance @ 20°c: 0.124 Ohm/km
Construction outer shield: tinned copper braiding
Core identification: HD 308 S2
Core lay-up: Concentric layers
Diameter conductor: 19.96 mm
Diameter over braiding: 37.5 mm
Diameter shield wires: 0.4 mm
Inductance: 0.193 mH/km
Insulation thickness: 2 mm
Nominal cross section conductor: 150 mm²
Nominal outer sheath thickness: 2.3 mm
Reel à 1: (16505 / 8713182080280)
Reel à 500: (16505H X 500/20 / 8713182080273)
Screening: Yes
Series: Shipboard cable
Shape of conductor: Sector-shaped
Sheath marking: {Length} TKF - 3X150 svs - 1,8/3 kV - CS 90 - mbzh - MarineLine YOZp HALOGEN FREE {Batch}
Standardization conductor material: IEC 60228
Standardization sheath material: IEC 60092-360
Tensile load: 6750 N