Indicative image 1-54-50-27-10-8
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 10x1,5 mm2
Uteco Code 1-54-50-27-10-8
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27108
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 27108
Description: 10 x 1,5 mm²
Cores: 10
Approx. Outer diameter: 17,3 mm
Core Colors: Black, with white printed numbers
Net weight (k: 0,439 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 105 mm
Bending radius during installation: 120 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Numbers
Diameter conductor: 1,57 mm
Diameter over braiding: 14,4 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,4 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 10x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-2 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 225 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1 MTR
Standard trade article: (27108 / 8713182123437)
Indicative image 1-54-50-27-10-9
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 12x1,5 mm2
Uteco Code 1-54-50-27-10-9
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27109
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 27109
Description: 12 x 1,5 mm²
Cores: 12
Approx. Outer diameter: 17,8 mm
Core Colors: Black, with white printed numbers
Net weight (k: 0,495 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 107 mm
Bending radius during installation: 124 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 1,57 mm
Diameter over braiding: 14 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,4 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 12x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-2 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 270 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1 MTR
Standard trade article: (27109 / 8713182123444)
Indicative image 1-54-50-27-10-9
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 12x1,5 mm2
Uteco Code 1-54-50-27-10-9
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27109
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 27109
Description: 12 x 1,5 mm²
Cores: 12
Approx. Outer diameter: 17,8 mm
Core Colors: Black, with white printed numbers
Net weight (k: 0,495 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 107 mm
Bending radius during installation: 124 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 1,57 mm
Diameter over braiding: 14 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,4 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 12x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-2 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 270 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1 MTR
Standard trade article: (27109 / 8713182123444)
Indicative image 1-54-50-27-17-3
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 14 G 1,5 mm2
Uteco Code 1-54-50-27-17-3
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27173
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 27173
Description: 14 G 1,5 mm²
Cores: 14
Approx. Outer diameter: 19,1 mm
Core Colors: Green/Yellow - Black, with white printed numbers
Net weight (k: 0,561 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 115 mm
Bending radius during installation: 135 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 1,57 mm
Diameter over braiding: 16 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,5 mm
Protective conductor: Yes
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 14x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-2 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 315 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1 MTR
Standard trade article: (27173 / 8713182275235)
Indicative image 1-54-50-27-17-3
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 14 G 1,5 mm2
Uteco Code 1-54-50-27-17-3
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27173
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 27173
Description: 14 G 1,5 mm²
Cores: 14
Approx. Outer diameter: 19,1 mm
Core Colors: Green/Yellow - Black, with white printed numbers
Net weight (k: 0,561 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 115 mm
Bending radius during installation: 135 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 1,57 mm
Diameter over braiding: 16 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,5 mm
Protective conductor: Yes
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 14x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-2 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 315 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1 MTR
Standard trade article: (27173 / 8713182275235)
Indicative image 1-54-50-27-11-0
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 16x1,5 mm2
Uteco Code 1-54-50-27-11-0
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27110
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 27110
Description: 16 x 1,5 mm²
Cores: 16
Approx. Outer diameter: 20,1 mm
Core Colors: Black, with white printed numbers
Net weight (k: 0,612 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 120 mm
Bending radius during installation: 140 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Numbers
Diameter conductor: 1,57 mm
Diameter over braiding: 17 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,5 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 16x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-1 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 360 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1000 MTR
Standard trade article: (27110 / 8713182122096)
Indicative image 1-54-50-27-11-0
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 16x1,5 mm2
Uteco Code 1-54-50-27-11-0
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27110
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 27110
Description: 16 x 1,5 mm²
Cores: 16
Approx. Outer diameter: 20,1 mm
Core Colors: Black, with white printed numbers
Net weight (k: 0,612 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 120 mm
Bending radius during installation: 140 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Numbers
Diameter conductor: 1,57 mm
Diameter over braiding: 17 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,5 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 16x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-1 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 360 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1000 MTR
Standard trade article: (27110 / 8713182122096)
Indicative image 1-54-50-27-17-4
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 19 G 1,5 mm2
Uteco Code 1-54-50-27-17-4
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27174
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 27174
Description: 19 G 1,5 mm²
Cores: 19
Approx. Outer diameter: 21,6 mm
Core Colors: Green/Yellow - Black, with white printed numbers
Net weight (k: 0,705 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 130 mm
Bending radius during installation: 150 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 1,57 mm
Diameter over braiding: 18,5 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,5 mm
Protective conductor: Yes
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 19G1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-1 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 428 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1 MTR
Standard trade article: (27174 / 8713182275242)
Indicative image 1-54-50-27-17-4
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 19 G 1,5 mm2
Uteco Code 1-54-50-27-17-4
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27174
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 27174
Description: 19 G 1,5 mm²
Cores: 19
Approx. Outer diameter: 21,6 mm
Core Colors: Green/Yellow - Black, with white printed numbers
Net weight (k: 0,705 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 130 mm
Bending radius during installation: 150 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 1,57 mm
Diameter over braiding: 18,5 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,5 mm
Protective conductor: Yes
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 19G1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-1 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 428 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1 MTR
Standard trade article: (27174 / 8713182275242)
Indicative image 1-54-50-27-11-1
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 19x1,5 mm2
Uteco Code 1-54-50-27-11-1
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27111
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 27111
Description: 19 x 1,5 mm²
Cores: 19
Approx. Outer diameter: 21,6 mm
Core Colors: Black, with white printed numbers
Net weight (k: 0,706 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 130 mm
Bending radius during installation: 150 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Numbers
Diameter conductor: 1,57 mm
Diameter over braiding: 18,5 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,5 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 19x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-1 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 428 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1 MTR
Standard trade article: (27111 / 8713182122102)
Indicative image 1-54-50-27-11-1
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 19x1,5 mm2
Uteco Code 1-54-50-27-11-1
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27111
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 27111
Description: 19 x 1,5 mm²
Cores: 19
Approx. Outer diameter: 21,6 mm
Core Colors: Black, with white printed numbers
Net weight (k: 0,706 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 130 mm
Bending radius during installation: 150 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Numbers
Diameter conductor: 1,57 mm
Diameter over braiding: 18,5 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,5 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 19x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-1 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 428 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1 MTR
Standard trade article: (27111 / 8713182122102)
Indicative image 1-54-50-27-11-2
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 24x1,5 mm2
Uteco Code 1-54-50-27-11-2
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27112
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 27112
Description: 24 x 1,5 mm²
Cores: 24
Approx. Outer diameter: 23,9 mm
Core Colors: Core colour: Black
Colour insulated wires: Black, with white printed numbers
Net weight (k: 0,852 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 145 mm
Bending radius during installation: 165 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Numbers
Diameter conductor: 1,57 mm
Diameter over braiding: 20,6 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,6 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 24x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-1 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 540 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1000 MTR
Standard trade article: (27112 / 8713182123451)
Indicative image 1-54-50-27-11-2
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 24x1,5 mm2
Uteco Code 1-54-50-27-11-2
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27112
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 27112
Description: 24 x 1,5 mm²
Cores: 24
Approx. Outer diameter: 23,9 mm
Core Colors: Core colour: Black
Colour insulated wires: Black, with white printed numbers
Net weight (k: 0,852 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 145 mm
Bending radius during installation: 165 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Numbers
Diameter conductor: 1,57 mm
Diameter over braiding: 20,6 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,6 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 24x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-1 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 540 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1000 MTR
Standard trade article: (27112 / 8713182123451)
Indicative image 1-54-50-27-12-1
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 27 x 2,5 mm2
Uteco Code 1-54-50-27-12-1
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27121
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 27121
Description: 27 x 2,5 mm²
Cores: 27
Approx. Outer diameter: 28,1 mm
Core Colors: Black, with white printed numbers
Net weight (k: 1,255 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 169 mm
Bending radius during installation: 197 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 9,3 Ohm/km
Conductor dc resistance @ 20°c: 7,41 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 2,04 mm
Diameter over braiding: 24,9 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,279 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 2,5 mm²
Nominal outer sheath thickness: 1,6 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 27x2,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-1 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 1.013 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1000 MTR
Standard trade article: (27121 / 8713182372224)
Indicative image 1-54-50-27-12-1
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 27 x 2,5 mm2
Uteco Code 1-54-50-27-12-1
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27121
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 27121
Description: 27 x 2,5 mm²
Cores: 27
Approx. Outer diameter: 28,1 mm
Core Colors: Black, with white printed numbers
Net weight (k: 1,255 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 169 mm
Bending radius during installation: 197 mm
Binde: Polyester tape
Conductor AC resistance at maximum continuous temperature: 9,3 Ohm/km
Conductor dc resistance @ 20°c: 7,41 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 2,04 mm
Diameter over braiding: 24,9 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,279 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 2,5 mm²
Nominal outer sheath thickness: 1,6 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 27x2,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-1 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 1.013 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1000 MTR
Standard trade article: (27121 / 8713182372224)
Indicative image 1-54-50-27-10-1
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 2x1,5 mm2
Uteco Code 1-54-50-27-10-1
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27101
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 27101
Description: 2 x 1,5 mm²
Cores: 2
Approx. Outer diameter: 9,7 mm
Core Colors: Blue - Brown
Net weight (k: 0,122 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 42 mm
Bending radius during installation: 74 mm
Binde: Polyester tape
Capacity: 55 nF/km
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colour
Diameter conductor: 1,57 mm
Diameter over braiding: 7,4 mm
Diameter shield wires: 0,2 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,1 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 2x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-2 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 45 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1 MTR
Standard trade article: (27101 / 8713182120832)
Indicative image 1-54-50-27-10-1
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 2x1,5 mm2
Uteco Code 1-54-50-27-10-1
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27101
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 27101
Description: 2 x 1,5 mm²
Cores: 2
Approx. Outer diameter: 9,7 mm
Core Colors: Blue - Brown
Net weight (k: 0,122 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 42 mm
Bending radius during installation: 74 mm
Binde: Polyester tape
Capacity: 55 nF/km
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colour
Diameter conductor: 1,57 mm
Diameter over braiding: 7,4 mm
Diameter shield wires: 0,2 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,1 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 2x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-2 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 45 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1 MTR
Standard trade article: (27101 / 8713182120832)
Indicative image 1-54-50-27-13-2
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 2x10 mm2
Uteco Code 1-54-50-27-13-2
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27132
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 27132
Description: 2 x 10 mm²
Cores: 2
Approx. Outer diameter: 15 mm
Core Colors: Blue - Brown
Net weight (k: 0,37 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 90 mm
Bending radius during installation: 105 mm
Binde: Polyester tape
Capacity: 82 nF/km
Conductor AC resistance at maximum continuous temperature: 2,3 Ohm/km
Conductor dc resistance @ 20°c: 1,83 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colour
Diameter conductor: 3,85 mm
Diameter over braiding: 12,4 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,244 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 10 mm²
Nominal outer sheath thickness: 1,3 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 2x10 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-2 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 300 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1000 MTR
Standard trade article: (27132 / 8713182122195)
Indicative image 1-54-50-27-13-2
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 2x10 mm2
Uteco Code 1-54-50-27-13-2
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27132
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 27132
Description: 2 x 10 mm²
Cores: 2
Approx. Outer diameter: 15 mm
Core Colors: Blue - Brown
Net weight (k: 0,37 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 90 mm
Bending radius during installation: 105 mm
Binde: Polyester tape
Capacity: 82 nF/km
Conductor AC resistance at maximum continuous temperature: 2,3 Ohm/km
Conductor dc resistance @ 20°c: 1,83 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colour
Diameter conductor: 3,85 mm
Diameter over braiding: 12,4 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,244 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 10 mm²
Nominal outer sheath thickness: 1,3 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 2x10 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-2 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 300 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1000 MTR
Standard trade article: (27132 / 8713182122195)
Indicative image 1-54-50-27-13-6
Category Cable
Type MarineLine YOZp X-FR 0,6/1 kV 2x16 mm2
Uteco Code 1-54-50-27-13-6
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 27136
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 27136
Description: 2 x 16 mm²
Cores: 2
Approx. Outer diameter: 17,2 mm
Core Colors: Blue - Brown
Net weight (k: 0,518 kg/m
Type: MarineLine YOZp X-FR 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Mica + XLHFFR
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Orange
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, fire resistant, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 104 mm
Bending radius during installation: 121 mm
Binde: Polyester tape
Capacity: 92 nF/km
Conductor AC resistance at maximum continuous temperature: 1,4 Ohm/km
Conductor dc resistance @ 20°c: 1,15 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colour
Diameter conductor: 4,85 mm
Diameter over braiding: 14,4 mm
Diameter shield wires: 0,3 mm
Fire resistant: IEC 60331-1/2
Inductance: 0,227 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 16 mm²
Nominal outer sheath thickness: 1,4 mm
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp X-FR 0,6/1 kV - 2x16 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22, 60331-2 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 480 N
Uv rating: Limited / Test duration 720 <= h <2000
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen free and low smoke • Fire resistant according IEC 60331 1/2 (≥ 120min.) • Tinned copper wire braid armouring • Different colour outer sheaths, other than orange, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: standard trade article: 1000 MTR
Standard trade article: (27136 / 8713182122232)