| Technical Specifications |
P... more Part number: 175639 Description: 4 x 185 svs + as95 Cores: 4 Approx. Outer diameter: 52,1 mm Core Colors: Blue - Brown - Black - Grey Net weight (k: 9,32 kg/m Type: Z1G-YMz1Kas Cca 0,6/1 kV Standardization: K42E-1-5-C / HD 604-5-C / NEN 3618 / EN 50575 Conductor material: Copper Conductor surface: Bare Conductor category: Class 2 = stranded Core insulation: Crosslinked polyethylene (XLPE) Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A Euro fire class according to EN 13501-6: Cca Permitted cable outer temperature, fixed: -40 / 70 °C Max. conductor temperature: 90 °C Nominal voltage U0: 0,6 kV Nominal voltage U: 1 kV Test voltage: 3,5 kV Colour outer sheath: Grey Product group: Power cable >= 1 kV, for permanent installation Application: Armored, halogen-free power cables 0,6/1 kV suitable for all applications described in NEN1010 low-voltage installations and where a higher fire safety is required. These cables are suitable as ground cables. Installation temperature: 0 / 70 °C UV-protection: NEN EN 50289-4-17A Euro class smoke production according to EN 13501-6: s1 Euro class flaming droplet: d1 Euro class acidity according to EN 13501-6: a1 UV resistant: Yes Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound Halogen free (acc. EN 60754-: IEC 60754-2 Low smoke (acc. EN 61034-2): IEC 61034-1 & IEC 61034-2 Armouring: Yes Bending radius after installation: 521 mm Bending radius during installation: 730 mm Conductor dc resistance @ 20°c: 0,0991 Ohm/km Diameter conductor: 18,5 mm Diameter over armouring (nom.): 49,9 mm Drain wire: No Inductance: 0,17 mH/km Insulation thickness: 1,6 mm Mutual capacitance (nominal): 0,45 µF/km Nominal cross section conductor: 185 mm² Outer sheath thickness: 2,7 mm Protective conductor: No Reel à 1000: (175639H X 1000/30 / 8713182280512) Reel à 500: (175639H X 500/20 / 8713182280529) Shape of conductor: Sector-shaped Sheath marking: {Length} TKF - Z1G-YMz1Kas Cca-s1,d1,a1 0,6/1 kV 4x185svs+as95 [-CE-] DoP: DoP0008 TWENKAPLUS KEMA-KEUR HALOGEN FREE {Batch} Shield dc resistance: 0,193 Ohm/km Standardization conductor material: IEC 60228 Uv rating: Mediocre / Test duration 2000 <= h < 3000 Armourin: Flat wire Characteristics: • KEMA-MARK • Halogen-free Conductor coding in accordance with hd 308 s2: Yes Current rating conditions: NEN 1010 Diameter over inner sheath (nom.): 46,9 mm Diameter over insulation (sector shaped: height sector): 18,8 mm Earthscreen construction: Stranded with fixed lay Flame retardant according to iec 60332-1-2: Yes Flame retardant according to iec 60332-3-22 (cat a): Yes Frequency: 50 Hz Inner sheath thickness: 1,2 mm Material inner sheath: Flame Retardant Halogen Free Polyolefin Compound Max. average cable diameter: 56,3 mm Max. short-circuit temperature conductor: 250 °C Min. average cable diameter: 52 mm Minimum installation temperature: 0 °C Minimum order: reel à 1000: 1 PCE Minimum order: reel à 500: 1 PCE Minimum order: standard trade article: 1 MTR Nominal equivalent cross section of reinforcement: 95 mm² Outdoor use permitted: Yes Sector angle conductor: 90 ° Sector hight conductor: 15,6 mm Sector width conductor: 21,8 mm Short-circuit current conductor (5 sec): 12,2 kA Short-circuit current shield (5 sec): 6,1 kA Standard trade article: (175639 / 8713182271589) Stranding: Stranded with fixed lay Suitable for underground installation: Yes Tensile force with pullinghead: 10.000 N Tensile force with pullingsleeve: 10.000 N
|