Indicative image NULL
Category Cable
Type MarineLine YOZp 0,6/1 kV 4 x 185 svs
Uteco Code 1-54-50-16-48-1
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16481
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16481
Description: 4 x 185 svs
Cores: 4
Approx. Outer diameter: 48 mm
Net weight (k: 7,848 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Cu
Conductor category: Class 2 = stranded
Core insulation: XLPE (VPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, in movement: -20 / 70 °C
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0.6 kV
Nominal voltage U: 1 kV
Test voltage: 3500 V
Colour outer sheath: Black
Product group: Shipboard low voltage cable
Application: Armoured, lightweight, reduced diameter low voltage cables for power and lighting applications in all ship areas where extra mechanical and EMC protection is needed. The tinned copper braid is highly corrosion resistant which ensures a long cable lifetime. Halogen-free and low-smoke , flame-retardant in fire conditions.
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 192 mm
Bending radius during installation: 336 mm
Binde: Polyester tape
Capacity: 93 nF/km
Conductor AC resistance at maximum continuous temperature: 0.124 Ohm/km
Conductor dc resistance @ 20°c: 0.0991 Ohm/km
Construction outer shield: tinned copper braiding
Core identification: HD 308 S2
Core lay-up: Concentric layers
Diameter conductor: 18.5 mm
Diameter over braiding: 43 mm
Diameter shield wires: 0.4 mm
Inductance: 0.17 mH/km
Insulation thickness: 1.6 mm
Nominal cross section conductor: 185 mm²
Nominal outer sheath thickness: 2.5 mm
Reel à 1: (16481 / 8713182221829)
Reel à 500: (16481H X 500/20 / 8713182221836)
Screening: Yes
Series: Shipboard cable
Shape of conductor: Sector-shaped
Sheath marking: {Length} TKF - 4X185 svs - 0,6/1 kV - CS 90 - mbzh - MarineLine YOZp HALOGEN FREE {Batch}
Standardization conductor material: IEC 60228
Standardization sheath material: IEC 60092-360
Tensile load: 11000 N
Indicative image 1-54-50-15-98-5
Category Cable
Type MarineLine YOZp 0,6/1 kV 4G1,5 mm2
Uteco Code 1-54-50-15-98-5
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 15985
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 15985
Description: 4 G 1,5 mm²
Cores: 4
Approx. Outer diameter: 9,7 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,149 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 39 mm
Bending radius during installation: 68 mm
Binde: Polyester tape
Capacity: 37 nF/km
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 1,56 mm
Diameter shield wires: 0,2 mm
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,1 mm
Protective conductor: Yes
Reel à 1000: (15985H X 1000/30 / 8713182050276)
Reel à 2000: (15985H X 2000/-30+60 / 8713182250515)
Reel à 500: (15985H X 500/20 / 8713182050252)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4G1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 90 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 2000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Nominal cross section pe conductor: 1,5 mm²
Number of pe conductors: 1
Standard trade article: (15985 / 8713182050269)
Indicative image 1-54-50-15-98-5
Category Cable
Type MarineLine YOZp 0,6/1 kV 4G1,5 mm2
Uteco Code 1-54-50-15-98-5
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 15985
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 15985
Description: 4 G 1,5 mm²
Cores: 4
Approx. Outer diameter: 9,7 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,149 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 39 mm
Bending radius during installation: 68 mm
Binde: Polyester tape
Capacity: 37 nF/km
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 1,56 mm
Diameter shield wires: 0,2 mm
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,1 mm
Protective conductor: Yes
Reel à 1000: (15985H X 1000/30 / 8713182050276)
Reel à 2000: (15985H X 2000/-30+60 / 8713182250515)
Reel à 500: (15985H X 500/20 / 8713182050252)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4G1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 90 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 2000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Nominal cross section pe conductor: 1,5 mm²
Number of pe conductors: 1
Standard trade article: (15985 / 8713182050269)
Indicative image 1-54-50-15-99-3
Category Cable
Type MarineLine YOZp 0,6/1 kV 4G10 mm2
Uteco Code 1-54-50-15-99-3
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 15993
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 15993
Description: 4 G 10 mm²
Cores: 4
Approx. Outer diameter: 16 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,567 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 64 mm
Bending radius during installation: 112 mm
Binde: Polyester tape
Capacity: 59 nF/km
Conductor AC resistance at maximum continuous temperature: 2,3 Ohm/km
Conductor dc resistance @ 20°c: 1,83 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 3,85 mm
Diameter over braiding: 13,4 mm
Diameter shield wires: 0,3 mm
Inductance: 0,244 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 10 mm²
Nominal outer sheath thickness: 1,3 mm
Protective conductor: Yes
Reel à 1000: (15993H X 1000/30 / 8713182200534)
Reel à 500: (15993H X 500/20 / 8713182200558)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4G10 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 600 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (15993 / 8713182200527)
Indicative image 1-54-50-15-99-3
Category Cable
Type MarineLine YOZp 0,6/1 kV 4G10 mm2
Uteco Code 1-54-50-15-99-3
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 15993
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 15993
Description: 4 G 10 mm²
Cores: 4
Approx. Outer diameter: 16 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,567 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 64 mm
Bending radius during installation: 112 mm
Binde: Polyester tape
Capacity: 59 nF/km
Conductor AC resistance at maximum continuous temperature: 2,3 Ohm/km
Conductor dc resistance @ 20°c: 1,83 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 3,85 mm
Diameter over braiding: 13,4 mm
Diameter shield wires: 0,3 mm
Inductance: 0,244 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 10 mm²
Nominal outer sheath thickness: 1,3 mm
Protective conductor: Yes
Reel à 1000: (15993H X 1000/30 / 8713182200534)
Reel à 500: (15993H X 500/20 / 8713182200558)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4G10 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 600 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Standard trade article: (15993 / 8713182200527)
Indicative image 1-54-50-15-99-4
Category Cable
Type MarineLine YOZp 0,6/1 kV 4G16 mm2
Uteco Code 1-54-50-15-99-4
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 15994
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 15994
Description: 4 G 16 mm²
Cores: 4
Approx. Outer diameter: 18,6 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,803 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 75 mm
Bending radius during installation: 130 mm
Binde: Polyester tape
Capacity: 68 nF/km
Conductor AC resistance at maximum continuous temperature: 1,4 Ohm/km
Conductor dc resistance @ 20°c: 1,15 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colour
Diameter conductor: 4,85 mm
Diameter over braiding: 15,8 mm
Diameter shield wires: 0,3 mm
Inductance: 0,227 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 16 mm²
Nominal outer sheath thickness: 1,4 mm
Protective conductor: Yes
Reel à 1000: (15994H X 1000/30 / 8713182200602)
Reel à 500: (15994H X 500/20 / 8713182200626)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4G16 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 960 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (15994 / 8713182200633)
Indicative image 1-54-50-15-99-4
Category Cable
Type MarineLine YOZp 0,6/1 kV 4G16 mm2
Uteco Code 1-54-50-15-99-4
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 15994
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 15994
Description: 4 G 16 mm²
Cores: 4
Approx. Outer diameter: 18,6 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,803 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 75 mm
Bending radius during installation: 130 mm
Binde: Polyester tape
Capacity: 68 nF/km
Conductor AC resistance at maximum continuous temperature: 1,4 Ohm/km
Conductor dc resistance @ 20°c: 1,15 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colour
Diameter conductor: 4,85 mm
Diameter over braiding: 15,8 mm
Diameter shield wires: 0,3 mm
Inductance: 0,227 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 16 mm²
Nominal outer sheath thickness: 1,4 mm
Protective conductor: Yes
Reel à 1000: (15994H X 1000/30 / 8713182200602)
Reel à 500: (15994H X 500/20 / 8713182200626)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4G16 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 960 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (15994 / 8713182200633)
Indicative image 1-54-50-15-98-8
Category Cable
Type MarineLine YOZp 0,6/1 kV 4G2,5 mm2
Uteco Code 1-54-50-15-98-8
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 15988
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 15988
Description: 4 G 2,5 mm²
Cores: 4
Approx. Outer diameter: 10,7 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,198 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 44 mm
Bending radius during installation: 76 mm
Binde: Polyester tape
Capacity: 44 nF/km
Conductor AC resistance at maximum continuous temperature: 9,3 Ohm/km
Conductor dc resistance @ 20°c: 7,41 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 2,04 mm
Diameter over braiding: 8,6 mm
Diameter shield wires: 0,2 mm
Inductance: 0,279 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 2,5 mm²
Nominal outer sheath thickness: 1,1 mm
Protective conductor: Yes
Reel à 1000: (15988H X 1000/30 / 8713182050399)
Reel à 500: (15988H X 500/20 / 8713182050375)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4G2,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 150 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (15988 / 8713182050382)
Indicative image 1-54-50-15-98-8
Category Cable
Type MarineLine YOZp 0,6/1 kV 4G2,5 mm2
Uteco Code 1-54-50-15-98-8
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 15988
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 15988
Description: 4 G 2,5 mm²
Cores: 4
Approx. Outer diameter: 10,7 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,198 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 44 mm
Bending radius during installation: 76 mm
Binde: Polyester tape
Capacity: 44 nF/km
Conductor AC resistance at maximum continuous temperature: 9,3 Ohm/km
Conductor dc resistance @ 20°c: 7,41 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 2,04 mm
Diameter over braiding: 8,6 mm
Diameter shield wires: 0,2 mm
Inductance: 0,279 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 2,5 mm²
Nominal outer sheath thickness: 1,1 mm
Protective conductor: Yes
Reel à 1000: (15988H X 1000/30 / 8713182050399)
Reel à 500: (15988H X 500/20 / 8713182050375)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4G2,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 150 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (15988 / 8713182050382)
Indicative image 1-54-50-16-52-3
Category Cable
Type MarineLine YOZp 0,6/1 kV 4G35 mm2
Uteco Code 1-54-50-16-52-3
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16523
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 16523
Description: 4 G 35 mm²
Cores: 4
Approx. Outer diameter: 29,4 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 2,005 kg/m
Type: MarineFlex YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 5 = flexible
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, flexible low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 118 mm
Bending radius during installation: 208 mm
Binde: FRNC filler
Capacity: 68 nF/km
Conductor AC resistance at maximum continuous temperature: 0,706 Ohm/km
Conductor dc resistance @ 20°c: 0,554 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 7,7 mm
Diameter over braiding: 26,3 mm
Diameter shield wires: 0,3 mm
Inductance: 0,211 mH/km
Insulation thickness: 0,9 mm
Nominal cross section conductor: 35 mm²
Nominal outer sheath thickness: 1,7 mm
Protective conductor: Yes
Reel à 500: (16523H X 500/20 / 8713182229634)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineFlex YOZp 0,6/1 kV - 4G35 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 2.100 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 5 conductors • Easy installation in tight spaces due to flexible conductors • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Nominal equivalent cross section of reinforcement: 18,6 mm²
Standard trade article: (16523 / 8713182229641)
Indicative image 1-54-50-16-52-3
Category Cable
Type MarineLine YOZp 0,6/1 kV 4G35 mm2
Uteco Code 1-54-50-16-52-3
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16523
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 16523
Description: 4 G 35 mm²
Cores: 4
Approx. Outer diameter: 29,4 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 2,005 kg/m
Type: MarineFlex YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 5 = flexible
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, flexible low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 118 mm
Bending radius during installation: 208 mm
Binde: FRNC filler
Capacity: 68 nF/km
Conductor AC resistance at maximum continuous temperature: 0,706 Ohm/km
Conductor dc resistance @ 20°c: 0,554 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 7,7 mm
Diameter over braiding: 26,3 mm
Diameter shield wires: 0,3 mm
Inductance: 0,211 mH/km
Insulation thickness: 0,9 mm
Nominal cross section conductor: 35 mm²
Nominal outer sheath thickness: 1,7 mm
Protective conductor: Yes
Reel à 500: (16523H X 500/20 / 8713182229634)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineFlex YOZp 0,6/1 kV - 4G35 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 2.100 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 5 conductors • Easy installation in tight spaces due to flexible conductors • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 500: 2 PCE
Minimum order: standard trade article: 1000 MTR
Nominal equivalent cross section of reinforcement: 18,6 mm²
Standard trade article: (16523 / 8713182229641)
Indicative image 1-54-50-15-99-2
Category Cable
Type MarineLine YOZp 0,6/1 kV 4G4 mm2
Uteco Code 1-54-50-15-99-2
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 15992
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 15992
Description: 4 G 4 mm²
Cores: 4
Approx. Outer diameter: 12,2 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,267 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 49 mm
Bending radius during installation: 86 mm
Binde: Polyester tape
Capacity: 47 nF/km
Conductor AC resistance at maximum continuous temperature: 5,8 Ohm/km
Conductor dc resistance @ 20°c: 4,61 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 2,55 mm
Diameter over braiding: 9,8 mm
Diameter shield wires: 0,2 mm
Inductance: 0,278 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 4 mm²
Nominal outer sheath thickness: 1,2 mm
Protective conductor: Yes
Reel à 1000: (15992H X 1000/30 / 8713182200572)
Reel à 500: (15992H X 500/20 / 8713182200596)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4G4 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 240 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (15992 / 8713182200565)
Indicative image 1-54-50-15-99-2
Category Cable
Type MarineLine YOZp 0,6/1 kV 4G4 mm2
Uteco Code 1-54-50-15-99-2
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 15992
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 15992
Description: 4 G 4 mm²
Cores: 4
Approx. Outer diameter: 12,2 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,267 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 49 mm
Bending radius during installation: 86 mm
Binde: Polyester tape
Capacity: 47 nF/km
Conductor AC resistance at maximum continuous temperature: 5,8 Ohm/km
Conductor dc resistance @ 20°c: 4,61 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 2,55 mm
Diameter over braiding: 9,8 mm
Diameter shield wires: 0,2 mm
Inductance: 0,278 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 4 mm²
Nominal outer sheath thickness: 1,2 mm
Protective conductor: Yes
Reel à 1000: (15992H X 1000/30 / 8713182200572)
Reel à 500: (15992H X 500/20 / 8713182200596)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4G4 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 240 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (15992 / 8713182200565)
Indicative image 1-54-50-15-99-0
Category Cable
Type MarineLine YOZp 0,6/1 kV 4G6 mm2
Uteco Code 1-54-50-15-99-0
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 15990
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 15990
Description: 4 G 6 mm²
Cores: 4
Approx. Outer diameter: 14,1 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,39 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 57 mm
Bending radius during installation: 99 mm
Binde: Polyester tape
Capacity: 50 nF/km
Conductor dc resistance @ 20°c: 3,08 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 3,06 mm
Diameter over braiding: 11,5 mm
Diameter shield wires: 0,3 mm
Inductance: 0,259 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 6 mm²
Nominal outer sheath thickness: 1,3 mm
Protective conductor: Yes
Reel à 1000: (15990H X 1000/30 / 8713182120368)
Reel à 500: (15990H X 500/20 / 8713182120375)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4G6 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 360 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Nominal cross section pe conductor: 6 mm²
Number of pe conductors: 1
Standard trade article: (15990 / 8713182124342)
Indicative image 1-54-50-15-99-0
Category Cable
Type MarineLine YOZp 0,6/1 kV 4G6 mm2
Uteco Code 1-54-50-15-99-0
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 15990
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 15990
Description: 4 G 6 mm²
Cores: 4
Approx. Outer diameter: 14,1 mm
Core Colors: Green/Yellow - Brown - Black - Grey
Net weight (k: 0,39 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 57 mm
Bending radius during installation: 99 mm
Binde: Polyester tape
Capacity: 50 nF/km
Conductor dc resistance @ 20°c: 3,08 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 3,06 mm
Diameter over braiding: 11,5 mm
Diameter shield wires: 0,3 mm
Inductance: 0,259 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 6 mm²
Nominal outer sheath thickness: 1,3 mm
Protective conductor: Yes
Reel à 1000: (15990H X 1000/30 / 8713182120368)
Reel à 500: (15990H X 500/20 / 8713182120375)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4G6 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 360 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Nominal cross section pe conductor: 6 mm²
Number of pe conductors: 1
Standard trade article: (15990 / 8713182124342)
Indicative image 1-54-50-16-11-3
Category Cable
Type MarineLine YOZp 0,6/1 kV 4x1,5 mm2
Uteco Code 1-54-50-16-11-3
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16113
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 16113
Description: 4 x 1,5 mm²
Cores: 4
Approx. Outer diameter: 9,7 mm
Core Colors: Blue - Brown - Black - Grey
Net weight (k: 0,149 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 39 mm
Bending radius during installation: 68 mm
Binde: Polyester tape
Capacity: 37 nF/km
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 1,56 mm
Diameter over braiding: 7,5 mm
Diameter shield wires: 0,2 mm
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,1 mm
Reel à 1000: (16113H X 1000/30 / 8713182048471)
Reel à 3500: (16113H X 3500 / 8713182250492)
Reel à 500: (16113H X 500/20 / 8713182048457)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 90 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 3500: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (16113 / 8713182048464)
Indicative image 1-54-50-16-11-3
Category Cable
Type MarineLine YOZp 0,6/1 kV 4x1,5 mm2
Uteco Code 1-54-50-16-11-3
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16113
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 16113
Description: 4 x 1,5 mm²
Cores: 4
Approx. Outer diameter: 9,7 mm
Core Colors: Blue - Brown - Black - Grey
Net weight (k: 0,149 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 39 mm
Bending radius during installation: 68 mm
Binde: Polyester tape
Capacity: 37 nF/km
Conductor AC resistance at maximum continuous temperature: 15 Ohm/km
Conductor dc resistance @ 20°c: 12,1 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 1,56 mm
Diameter over braiding: 7,5 mm
Diameter shield wires: 0,2 mm
Inductance: 0,307 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 1,5 mm²
Nominal outer sheath thickness: 1,1 mm
Reel à 1000: (16113H X 1000/30 / 8713182048471)
Reel à 3500: (16113H X 3500 / 8713182250492)
Reel à 500: (16113H X 500/20 / 8713182048457)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4x1,5 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 90 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 3500: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (16113 / 8713182048464)
Indicative image 1-54-50-16-14-0
Category Cable
Type MarineLine YOZp 0,6/1 kV 4x10 mm2
Uteco Code 1-54-50-16-14-0
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16140
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 16140
Description: 4 x 10 mm²
Cores: 4
Approx. Outer diameter: 16,2 mm
Core Colors: Blue - Brown - Black - Grey
Net weight (k: 0,565 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 67 mm
Bending radius during installation: 117 mm
Binde: Polyester tape
Capacity: 59 nF/km
Conductor AC resistance at maximum continuous temperature: 2,3 Ohm/km
Conductor dc resistance @ 20°c: 1,83 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 3,85 mm
Diameter over braiding: 13,4 mm
Diameter shield wires: 0,3 mm
Inductance: 0,244 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 10 mm²
Nominal outer sheath thickness: 1,3 mm
Reel à 1000: (16140H X 1000/30 / 8713182049553)
Reel à 500: (16140H X 500/20 / 8713182049539)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4x10 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 600 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (16140 / 8713182049546)
Indicative image 1-54-50-16-14-0
Category Cable
Type MarineLine YOZp 0,6/1 kV 4x10 mm2
Uteco Code 1-54-50-16-14-0
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16140
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Available from stock
Technical Specifications P... more
Part number: 16140
Description: 4 x 10 mm²
Cores: 4
Approx. Outer diameter: 16,2 mm
Core Colors: Blue - Brown - Black - Grey
Net weight (k: 0,565 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 67 mm
Bending radius during installation: 117 mm
Binde: Polyester tape
Capacity: 59 nF/km
Conductor AC resistance at maximum continuous temperature: 2,3 Ohm/km
Conductor dc resistance @ 20°c: 1,83 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colours and numbers
Diameter conductor: 3,85 mm
Diameter over braiding: 13,4 mm
Diameter shield wires: 0,3 mm
Inductance: 0,244 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 10 mm²
Nominal outer sheath thickness: 1,3 mm
Reel à 1000: (16140H X 1000/30 / 8713182049553)
Reel à 500: (16140H X 500/20 / 8713182049539)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4x10 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 600 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (16140 / 8713182049546)
Indicative image 1-54-50-16-14-4
Category Cable
Type MarineLine YOZp 0,6/1 kV 4x16 mm2
Uteco Code 1-54-50-16-14-4
Maker TKF CONNECTIVITY SOLUTIONS (B.V. TWENTSCHE KABELFABRIEK)
Item Code 16144
Datasheet  download
Leaflet -
Manual -
Certificates -
Brochure -
Item Availability Upon Request
Technical Specifications P... more
Part number: 16144
Description: 4 x 16 mm²
Cores: 4
Approx. Outer diameter: 18,6 mm
Core Colors: Blue - Brown - Black - Grey
Net weight (k: 0,813 kg/m
Type: MarineLine YOZp 0,6/1 kV
Standardization: IEC 60092-350/-360/-353
Conductor material: Copper
Conductor surface: Bare
Conductor category: Class 2 = stranded
Core insulation: Crosslinked polyethylene (XLPE)
Flame retardant: IEC 60332-1 / IEC 60332-3-22 Cat. A
Permitted cable outer temperature, fixed: -40 / 70 °C
Max. conductor temperature: 90 °C
Nominal voltage U0: 0,6 kV
Nominal voltage U: 1 kV
Test voltage: 3,5 kV
Colour outer sheath: Black
Product group: Power cable >= 1 kV, for permanent installation
Application: Lightweight, armoured, reduced diameter low voltage power cables for power and lighting applications in all ship areas.
Installation temperature: -20 / 50 °C
Transportation and storage temperature: -40 / 50 °C
UV-protection: NEN EN 50289-4-17A
UV resistant: Yes
Material outer sheath: Flame Retardant Halogen Free Polyolefin Compound
Halogen free (acc. EN 60754-: IEC 60754-1/2
Low smoke (acc. EN 61034-2): IEC 61034-2
Bending radius after installation: 77 mm
Bending radius during installation: 135 mm
Binde: Polyester tape
Capacity: 68 nF/km
Conductor AC resistance at maximum continuous temperature: 1,4 Ohm/km
Conductor dc resistance @ 20°c: 1,15 Ohm/km
Construction outer shield: Tinned copper braiding
Core identification: Colour
Diameter conductor: 4,85 mm
Diameter over braiding: 15,8 mm
Diameter shield wires: 0,3 mm
Inductance: 0,227 mH/km
Insulation thickness: 0,7 mm
Nominal cross section conductor: 16 mm²
Nominal outer sheath thickness: 1,4 mm
Reel à 1000: (16144H X 1000/30 / 8713182049713)
Reel à 500: (16144H X 500/20 / 8713182049690)
Screening: Yes
Shape of conductor: Round
Sheath marking: {Length} 0000 TKF - MarineLine YOZp 0,6/1 kV - 4x16 mm² +90 º C - LSHF - IEC 60092-353, 60332-3-22 - {Batch}
Standardization conductor material: IEC 60228
Tensile load: 960 N
Uv rating: Very good / Test duration >= 6000 h
Characteristics: • Class 2 conductors • Lightweight, reduced diameter • Halogen-free and low smoke, flame retardant • Tinned copper wire braid armouring • Excellent abrasion resistance • Different colour outer sheaths, other than black, available on request • DC voltage: 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Conductor coding in accordance with hd 308 s2: Yes
Dc voltage (stated in description): 0,9/1,5 kV (if voltage to earth does not exceed 0,9 kV)
Minimum order: reel à 1000: 1 PCE
Minimum order: reel à 500: 1 PCE
Minimum order: standard trade article: 1 MTR
Standard trade article: (16144 / 8713182049706)